A modern furnace starts in a fixed order, and knowing the order tells you where it is stopping. The thermostat calls for heat. A small exhaust fan, the inducer, starts and a pressure switch confirms the vent is clear. The ignitor glows orange or sparks. The gas valve opens and the burners light. A flame sensor then has a few seconds to prove there is a flame. Only after that does the main blower start and push warm air through the house. Your furnace is failing at the proving step or just after it.

Why does my furnace start and then shut off right away?

Most often because the flame sensor is coated. The sensor is a thin metal rod that sits in the flame of the last burner. The control board passes a tiny current through the flame to the rod, and that current is its proof that gas is burning. Over a few heating seasons the rod picks up a film of oxide and dust that weakens the signal. The burners light normally, the board reads no flame, and it shuts the gas off within seconds. Carrier, Lennox and Trane all list a dirty flame sensor among the causes to check when a furnace lights and cuts out.

The furnace then tries again. Carrier notes that most furnaces retry two or three times before locking out. During lockout the burners stay off, and on many models the blower runs for a while to clear the heat exchanger, which is why you may feel cool air from the vents.

How long does it stay lit? Match the pattern

Furnace lights then shuts off: pattern, likely cause, what to do
What you seeLikely causeCheck it yourself?Who fixes it
Burners light, go out within 3 to 10 seconds, and this repeats two or three timesDirty or failing flame sensorRead the light code firstGas technician: clean or replace the sensor
Burners run for a few minutes, then go out while the fan keeps blowingOverheating: the high-limit switch is opening because air cannot moveYes: change the filter, open every supply and return ventGas technician if a new filter does not fix it
Inducer fan starts, then stops before anything glows; worse in wind, deep cold or heavy snowPressure switch: blocked intake or exhaust pipe, or a blocked condensate drainYes: clear snow and ice from the pipes outsideGas technician if the pipes are clear
Clicking or an orange glow, but the burners never lightFailed ignitor or no gas reaching the burnersCheck other gas appliances workGas technician
Only some burners light, or the flame is yellow, lazy or lifts off the burnersDirty burners, a venting problem or a heat exchanger problemNo: switch the furnace offGas technician, before you use it again

What can I safely check myself?

  1. Read the status light before you touch the power. Most furnaces have a small window in the lower door with a light that blinks a code, and the chart is on the inside of the door. On many boards, switching the power off erases the code. Write it down or film it.
  2. Check the filter. Slide it out and hold it to a light; if you cannot see through it, replace it. A clogged filter makes the furnace overheat and shut its burners off.
  3. Open the vents. Make sure supply registers and return grilles are open and not covered by rugs or furniture.
  4. Look outside. A high-efficiency furnace breathes through two plastic pipes on the side of the house. Clear snow, ice, leaves or a nest from both, by hand and gently.
  5. Check the thermostat is set to heat with fresh batteries, and that the furnace switch (it looks like a light switch, on or near the furnace) is on.
  6. Reset once. Turn the furnace switch off for a minute, then on. If it lights and locks out again, stop resetting it and book a technician. Repeated resets only repeat the failed start.

Can I clean a furnace flame sensor myself?

The job itself is small: with the power off, the sensor is removed with one screw, the rod is wiped with a fine abrasive pad and it goes back in. Manufacturers' own guides describe it. But it means opening the burner compartment of a gas appliance, and the same symptom can come from a cracked sensor insulator, a poor ground, low gas pressure or a failing control board, which cleaning will not fix. In Ontario, gas appliances are serviced by technicians certified by the Technical Standards and Safety Authority (TSSA), working for a TSSA-registered contractor. If you are not sure what you are looking at, or the furnace still drops out after a cleaning, leave it to a gas technician. Never bypass or jump a flame sensor or any safety switch to keep the heat on.

Is it dangerous if my furnace keeps trying to light?

The shutdown is the safety system working: the board closes the gas valve precisely because it cannot confirm the flame, and it locks out so that unburned gas does not collect. The risk comes from working around it, by resetting again and again or by running a furnace that shows a yellow or lifting flame. The other risk is the house itself. With no heat in an Ontario cold snap, pipes on outside walls can freeze. While you wait for the visit, keep interior doors and the cabinet doors under sinks open, and use an electric space heater only on its own outlet and never unattended.

What does the repair involve, and what does it cost on Doyo?

A technician reads the code, measures the flame signal and the gas pressure, and cleans or replaces the part at fault. A flame sensor is one of the smaller furnace repairs; an ignitor, a pressure switch or an inducer motor costs more, and a control board more again. Our furnace repair cost guide gives the typical Ontario ranges for each.

On Doyo, Furnace Repair is priced by written quote: you describe what the furnace does, and you get the price in writing before the repair starts. If the furnace has not been serviced this season, Furnace Maintenance is $201.25, the full price with Doyo's fee included, and a seasonal tune-up is when a technician would normally clean the flame sensor, so ask for it when you book. Gas work in Ontario requires a TSSA-registered contractor and a certified gas technician, and Doyo checks the technician's certificate before they are offered heating work.

Questions people ask

It is going through its ignition trials. Each time, the board lights the burners and looks for a flame signal; when it does not get one, it closes the gas valve and tries again. After two or three failed tries most furnaces lock out for safety. A dirty flame sensor is the usual cause, followed by a weak ignitor or a gas supply problem.

Describe what your furnace does and get a written priceStart

Sources

  1. Carrier: Furnace flame sensor, what it is and why it fails · carrier.com
  2. Trane: Furnace main burner shuts off after ignition · trane.com
  3. Lennox: Furnace flame sensor · lennox.com
  4. TSSA: Find a Registered Fuels Contractor · tssa.org
  5. Enbridge Gas: If you smell gas · enbridgegas.com